home *** CD-ROM | disk | FTP | other *** search
-
- TRANGO-P5M-MIB DEFINITIONS ::= BEGIN
-
- IMPORTS
- MODULE-IDENTITY,
- OBJECT-TYPE,
- OBJECT-IDENTITY,
- Unsigned32,
- NOTIFICATION-TYPE,
- enterprises
- FROM SNMPv2-SMI
-
- NOTIFICATION-GROUP,
- MODULE-COMPLIANCE
- FROM SNMPv2-CONF;
-
- -- islModules, islGeneric, islTrango
- -- FROM ISL-GLOBAL-REG;
-
- DisplayString ::= OCTET STRING
-
- -- *******************************************************************
- -- * Trango module
- -- *******************************************************************
- trango OBJECT IDENTIFIER ::= { enterprises 5454 }
- tbw OBJECT IDENTIFIER ::= { trango 1 }
- trangoModules OBJECT IDENTIFIER ::= { trango 10 }
-
- trangoP5M MODULE-IDENTITY
- LAST-UPDATED "200508220000Z"
- ORGANIZATION "Trango Corporation"
- CONTACT-INFO "
- Name: Trango Systems, Inc.
- Address: 15070 Avenue of Science
- Zip: CA 92128
- City: San Diego
- Country: U.S.A.
- Phone: +1-858-653-3900
- e-mail: techsupport@trangobroadband.com
- This is added by Eclips
- "
- DESCRIPTION "The Trango SNMP General MIB Module for Atlas Point to Point P5M"
- REVISION "200602150000Z"
- DESCRIPTION "The latest version of this MIB module."
- REVISION "200408270000Z"
- DESCRIPTION "Initial version."
- ::= { trangoModules 10 }
-
- -- Trango Atlas Point to Point
-
- p5m OBJECT IDENTIFIER ::= { tbw 40 }
-
- -- *******************************************************************
- -- ** System Information ** islTrango.p5m.sys
- -- *******************************************************************
- sys OBJECT IDENTIFIER ::= { p5m 1 }
-
- -- **** Version **** islTrango.p5m.sys.1
-
- ver OBJECT IDENTIFIER ::= { sys 1 }
-
- verUintType OBJECT-TYPE
- SYNTAX INTEGER { mu(1), ru(0) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "MU/RU"
- ::= { ver 1 }
-
- verHW OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(2))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Hardware Version"
- ::= { ver 2 }
-
- verFW OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..80))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Main firmware version <version code>H<hardware version>D<date code>"
- ::= { ver 3 }
-
- -- verFWChecksum OBJECT-TYPE
- -- SYNTAX OCTET STRING (SIZE(4))
- -- MAX-ACCESS read-only
- -- STATUS current
- -- DESCRIPTION "Firmware Checksum"
- -- ::= { ver 5 }
-
- -- **** MAC Address **** islTrango.p5m.sys.2
-
- sysMAC OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(6))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "MAC Address"
- ::= { sys 2 }
-
- -- **** Default Opmode **** islTrango.p5m.sys.3
-
- sysDefaultOpmode OBJECT-TYPE
- SYNTAX INTEGER { on(1), off(0) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Default Opmode"
- ::= { sys 3 }
-
- -- **** Current Opmode **** islTrango.p5m.sys.4
-
- sysCurrentOpmode OBJECT-TYPE
- SYNTAX INTEGER { on(1), off(0) }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Current Opmode"
- ::= { sys 4 }
-
- sysActivateOpmode OBJECT-TYPE
- SYNTAX INTEGER { deactivated(0), activated(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Turn on opmode"
- ::= { sys 5 }
-
- sysReadCommStr OBJECT-TYPE
- SYNTAX DisplayString (SIZE (1..32))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "SNMP agent read community string. It is used for authentication purpose."
- ::= { sys 6 }
-
- sysWriteCommStr OBJECT-TYPE
- SYNTAX DisplayString (SIZE (1..32))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "SNMP agent write community string. It is used for authentication purpose."
- ::= { sys 7 }
-
- -- **** Switches **** islTrango.p5m.sys.8
-
- syssw OBJECT IDENTIFIER ::= { sys 8 }
-
- sysswTftpServerEnable OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Enable or disable to receive code or fileset download."
- ::= { syssw 1 }
-
- sysswAutoRateShiftingEnable OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Switch to different speed rate automatically
- to get the maximum throughput value."
- ::= { syssw 2 }
-
- sysswAutoScanMUSignal OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Remote unit scans to all channel frequencies
- to listen to its master's heart-beat (RU Only)."
- ::= { syssw 3 }
-
- sysswRSSILEDFlashEnable OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Enabling RSSI LED to blink based on its current RSSI value."
- ::= { syssw 4 }
-
- sysswARQEnable OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "ARQ Enable (MU Only)"
- ::= { syssw 8 }
-
- -- **** Traffic **** islTrango.p5m.sys.9
-
- systraffic OBJECT IDENTIFIER ::= { sys 9 }
-
- systrafficEthInOctets OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Number of payload octets received on Ethernet port."
- ::= { systraffic 1 }
-
- systrafficEthOutOctets OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Number of payload octets transmitted on Ethernet port."
- ::= { systraffic 2 }
-
- systrafficRfInOctets OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Number of octets of remote's payload received from RF port."
- ::= { systraffic 3 }
-
- systrafficRfOutOctets OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Number of octets of remote's payload transmitted to RF port."
- ::= { systraffic 4 }
-
- sysReserved1 OBJECT-TYPE
- SYNTAX INTEGER { no(0), yes(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Save system setting values to Flash and activate the settings.
- Not supported in this release."
- DEFVAL { no }
- ::= { sys 11 }
-
- sysReboot OBJECT-TYPE
- SYNTAX INTEGER { deactivated(0), activated(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Reboot the master unit."
- DEFVAL { deactivated }
- ::= { sys 12 }
-
- -- **** IPConfig **** islTrango.p5m.sys.13
-
- sysipconfig OBJECT IDENTIFIER ::= { sys 13 }
-
- sysipconfigIpAddress OBJECT-TYPE
- SYNTAX IpAddress
- -- MAX-ACCESS read-only
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "IP address"
- ::= { sysipconfig 1 }
-
- sysipconfigSubnet OBJECT-TYPE
- SYNTAX IpAddress
- -- MAX-ACCESS read-only
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Subnet mask"
- ::= { sysipconfig 2 }
-
- sysipconfigDefaultGateway OBJECT-TYPE
- SYNTAX IpAddress
- -- MAX-ACCESS read-only
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Default gateway"
- ::= { sysipconfig 3 }
-
- sysipconfigChange OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..80))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "New IP Address, Subnet Mask and Default Gateway
- xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx"
- ::= { sysipconfig 4 }
-
- -- ************************************************************
- sysRemarks OBJECT-TYPE
- SYNTAX DisplayString (SIZE (0..80))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Remarks"
- ::= { sys 14 }
-
- -- ************************************************************
- sysEncryptEnable OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Enable/Disable Encrypt"
- ::= { sys 15 }
-
- sysEncryptKey OBJECT-TYPE
- SYNTAX Opaque (SIZE (16))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Encrypt Key"
- ::= { sys 16 }
-
- -- *******************************************************************
- -- ** OIDs used by M5580M.
- -- ** sys 17 to 32
- -- *******************************************************************
-
- sysPoE OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Unit's current PoE reading in Voltage."
- ::= { sys 33 }
-
- sysTemperature OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Unit's current temperature reading in Celsius."
- ::= { sys 34 }
-
- -- *******************************************************************
- -- ** RF islTrango.p5m.rf
- -- *******************************************************************
- rf OBJECT IDENTIFIER ::= { p5m 2 }
-
- rfPeerDeviceID OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Device ID of Remote Unit"
- ::= { rf 1 }
-
- rfActiveChannel OBJECT-TYPE
- SYNTAX INTEGER (1..24)
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "It specifies the current active channel number."
- ::= { rf 2 }
-
- rfActivePolarization OBJECT-TYPE
- SYNTAX DisplayString (SIZE(1))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "It specifies the current polarization."
- ::= { rf 3 }
-
- rfSpeed OBJECT-TYPE
- SYNTAX INTEGER (6 | 12 | 18 | 24 | 36 | 48 | 54)
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "It specifies the rf speed."
- ::= { rf 4 }
-
- rfTxPower OBJECT-TYPE
- SYNTAX INTEGER (-30..40)
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "It specifies tx power. And it will be limited by Min/Max by different band"
- ::= { rf 5 }
-
- rfTxMIR OBJECT-TYPE
- SYNTAX INTEGER (100..50000)
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Max Tx Information Rate in Kbps"
- ::= { rf 6 }
-
- rfNumberOfChannel OBJECT-TYPE
- SYNTAX INTEGER (1..24)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "number of Channel"
- ::= { rf 7 }
-
- -- **** Channel Table **** islTrango.p5m.rf.5
-
- rfChannelTable OBJECT-TYPE
- SYNTAX SEQUENCE OF ChannelTableEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "Channel Table"
- ::= { rf 8 }
-
- rfChannelTableEntry OBJECT-TYPE
- SYNTAX ChannelTableEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "An entry of Channel Table."
- INDEX { rfChannelTableIndex }
- ::= { rfChannelTable 1 }
-
- ChannelTableEntry ::=
- SEQUENCE {
- rfChannelTableIndex INTEGER,
- rfChannelFrequency INTEGER
- }
-
- rfChannelTableIndex OBJECT-TYPE
- SYNTAX INTEGER (1..24)
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "index of Channel Table"
- ::= { rfChannelTableEntry 1 }
-
- rfChannelFrequency OBJECT-TYPE
- SYNTAX INTEGER (5150..5875)
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Frequency (MHz)"
- ::= { rfChannelTableEntry 2 }
-
- -- *******************************************************************
- -- *********************** Regulatory ********************************
- -- *******************************************************************
-
- rfAreaCode OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "area code which specify band regulatory"
- ::= { rf 9 }
-
- -- *******************************************************************
-
- rfBandTable OBJECT-TYPE
- SYNTAX SEQUENCE OF BandTableEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "4 Band Tables"
- ::= { rf 10 }
-
- rfBandTableEntry OBJECT-TYPE
- SYNTAX BandTableEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "An entry of Band Table."
- INDEX { rfBandTableIndex }
- ::= { rfBandTable 1 }
-
- BandTableEntry ::=
- SEQUENCE {
- rfBandTableIndex INTEGER,
- rfBandRangeMin INTEGER,
- rfBandRangeMax INTEGER,
- rfBandEnable INTEGER,
- rfBandTxPowerMin INTEGER,
- rfBandTxPowerMaxCCK INTEGER,
- rfBandTxPowerMaxBPSK INTEGER,
- rfBandTxPowerMaxQPSK INTEGER,
- rfBandTxPowerMax16QAM INTEGER,
- rfBandTxPowerMax64QAM INTEGER
- }
-
- rfBandTableIndex OBJECT-TYPE
- SYNTAX INTEGER (1..4)
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "index of Band Table"
- ::= { rfBandTableEntry 1 }
-
- rfBandRangeMin OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Min Frequency of Band"
- ::= { rfBandTableEntry 2 }
-
- rfBandRangeMax OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Max Frequency of Band"
- ::= { rfBandTableEntry 3 }
-
- rfBandEnable OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Band availability"
- ::= { rfBandTableEntry 4 }
-
- rfBandTxPowerMin OBJECT-TYPE
- SYNTAX INTEGER (-128..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Min Tx Power"
- ::= { rfBandTableEntry 5 }
-
- rfBandTxPowerMaxCCK OBJECT-TYPE
- SYNTAX INTEGER (-128..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Max Tx Power for CCK"
- ::= { rfBandTableEntry 6 }
-
- rfBandTxPowerMaxBPSK OBJECT-TYPE
- SYNTAX INTEGER (-128..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Max Tx Power for BPSK"
- ::= { rfBandTableEntry 7 }
-
- rfBandTxPowerMaxQPSK OBJECT-TYPE
- SYNTAX INTEGER (-128..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Max Tx Power for QPSK"
- ::= { rfBandTableEntry 8 }
-
- rfBandTxPowerMax16QAM OBJECT-TYPE
- SYNTAX INTEGER (-128..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Max Tx Power for 16 QAM"
- ::= { rfBandTableEntry 9 }
-
- rfBandTxPowerMax64QAM OBJECT-TYPE
- SYNTAX INTEGER (-128..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Max Tx Power for 64 QAM"
- ::= { rfBandTableEntry 10 }
-
- -- *******************************************************************
-
- rfRSSI OBJECT-TYPE
- SYNTAX INTEGER (-128..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "RSSI (in dBm)."
- ::= { rf 12 }
-
- rfAssociated OBJECT-TYPE
- SYNTAX INTEGER { no(0), yes(1) }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Association Status"
- ::= { rf 13 }
-
- -- *******************************************************************
- -- ** RU Management islTrango.p5m.ru (MU Only)
- -- *******************************************************************
- ru OBJECT IDENTIFIER ::= { p5m 3 }
-
- ruReserved2 OBJECT-TYPE
- SYNTAX INTEGER { deactivated(0), activated(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Perform Power Leveling RU. Not supported in this release."
- ::= { ru 1 }
-
- ruReserved3 OBJECT-TYPE
- SYNTAX INTEGER { deactivated(0), activated(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Reboot RU. Not supported in this release."
- ::= { ru 2 }
-
- ruReserved4 OBJECT-TYPE
- SYNTAX INTEGER ( 0..100 )
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Distance of RU in mile. Not supported in this release."
- ::= { ru 3 }
-
- -- *******************************************************************
- -- ** MU/RU Notifications
- -- *******************************************************************
- trap OBJECT IDENTIFIER ::= { p5m 4 }
- maintenance OBJECT IDENTIFIER ::= { p5m 5 }
- trangoEvents OBJECT IDENTIFIER ::= { p5m 6 }
- trangoEventsV2 OBJECT IDENTIFIER ::= { trangoEvents 0 }
-
- trapTrapDstTable OBJECT-TYPE
- SYNTAX SEQUENCE OF TrapTrapDstEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "This table allows control of the reporting of traps
- generated by monitoring the operation of master or remote."
- ::= { trap 1 }
-
- trapTrapDstEntry OBJECT-TYPE
- SYNTAX TrapTrapDstEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "Allows configuration of the reporting mechanisms for a particular event."
- INDEX { trapTrapDstIndex }
- ::= { trapTrapDstTable 1 }
-
- TrapTrapDstEntry ::= SEQUENCE {
- trapTrapDstIndex INTEGER,
- trapTrapDstEnabling INTEGER
- }
-
- trapTrapDstIndex OBJECT-TYPE
- SYNTAX INTEGER (1..2)
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "Event Index."
- ::= { trapTrapDstEntry 1 }
-
- trapTrapDstEnabling OBJECT-TYPE
- SYNTAX INTEGER { disabled(0), enabled(1) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Enabled or Disabled sending trap."
- ::= { trapTrapDstEntry 2 }
-
- trapTrapDstIpAddress OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "The IP Address of a management station to send traps to."
- ::= { trap 2 }
-
- trapTrapCommStr OBJECT-TYPE
- SYNTAX DisplayString (SIZE (1..32))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Trap community string."
- ::= { trap 3 }
-
- maintenanceLinkControl OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..80))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Link Test Summary Data."
- ::= { maintenance 1 }
-
- maintenanceSiteSurveySummary1 OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..128))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Site Survey Summary Data."
- ::= { maintenance 2 }
-
- maintenanceServiceEnable OBJECT-TYPE
- SYNTAX INTEGER { start(1), stop(2), changed(3), boareset(4) }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Enable or disable system service."
- ::= { maintenance 3 }
-
- maintenanceSiteSurveySummary2 OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..128))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Site Survey Summary Data."
- ::= { maintenance 4 }
-
- maintenanceSiteSurveySummary3 OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..128))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Site Survey Summary Data."
- ::= { maintenance 5 }
-
- maintenanceSiteSurveySummary4 OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (0..128))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Site Survey Summary Data."
- ::= { maintenance 6 }
-
- maintenanceSerialNumber OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Atlas Board Serial Number."
- ::= { maintenance 7 }
-
- maintenanceUNIIMaxPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "UNII Maximum Power."
- ::= { maintenance 8 }
-
- masterEvent NOTIFICATION-TYPE
- OBJECTS {
- sysCurrentOpmode
- }
- STATUS current
- DESCRIPTION "This notification signifies that the master unit generated a report."
- ::= { trangoEventsV2 1 }
-
- remoteEvent NOTIFICATION-TYPE
- OBJECTS {
- -- TBD
- sysCurrentOpmode
- }
- STATUS current
- DESCRIPTION "This notification signifies that the remote unit generated a report."
- ::= { trangoEventsV2 2 }
-
- -- *******************************************************************
- -- ** Groups and compliances
- -- *******************************************************************
- trangoConf OBJECT IDENTIFIER ::= { p5m 7 }
- trangoGroups OBJECT IDENTIFIER ::= { trangoConf 1 }
- trangoCompl OBJECT IDENTIFIER ::= { trangoConf 2 }
-
- eventReportingGroupV2 NOTIFICATION-GROUP
- NOTIFICATIONS {
- masterEvent,
- remoteEvent
- }
- STATUS current
- DESCRIPTION "Notification group."
- ::= { trangoGroups 1 }
-
- versionComplV2 MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION "The implementation requirements for Trango products that support SNMP."
- MODULE -- this module
- MANDATORY-GROUPS {
- eventReportingGroupV2
- }
- ::= { trangoCompl 1 }
-
- END
-
-